We are prominent manufacturer and supplier ofCombustion Gas Analyzers. These are highly appreciated by our clients, Client satisfaction is our main motive, keeping this in mind we deliver international quality product to our valuable clients. These are available at reasonable price.
Features:User friendly
Specifications:
Interchangeable sensors: O2, COH2, NO, NO2, SO2, CH4 (optional)
KEY POINTS
Intuitive graphic interfaceLED on the probe handle to light dark areas Built-in printerAuto-zeroing in the flueFEATURES OF THE INSTRUMENTGAS – Autozeroing in the flue- CO dilution up to 5% 1Flue gases CO and CO2,ambient CO maxInterchangeable sensors: long life O2,COH2, NO, NO2, SO2, CH4 (optional)Excess airLossesEfficiency > 100%PRESSURE Differential pressuremeasurementHigh accuracy draft measurementwith autozero by solenoid valveGas flow auto-settingTEMPERATURE Ambient temperature Flue gas temperature Delta Temperature DHW Temperature2 thermocouplesDew pointtemperatureOTHERFUNCTIONS15 programmedcombustibles2Adding 5 combustiblesby the userOpacity index Single connector Interchangeable probe 2 Go memory (100 000 measurements)CO-H2, NO, NO2, SO2, CH4interchangeable sensorsO2 long life sensorCO dilution2Combustibles: Sahara/Fos-sur-Mer Natural Gas, Groningen Natural Gas, Russia/North Sea Natural Gas, Propane, LPG, Butane, Light Oil, Heavy Oil, Bituminous coal, Hard coal, Coke gas, Bio fuel 5%,Wood 20%, Wood-chip 21%, Pellet 8%1With an accuracy of ±10% of the measurementGas flow auto-setting
Parameters Sensor Measuring range Resolution Accuracy*T90 responsetimeLong life O2 Electrochemical From 0 % to 21 % 0.1 % vol. ±0.2 % vol. 30 sCO(with H2compensation)Electrochemical From 0 to 8000 ppm 1 ppm From 0 to 200 ppm: ±10 ppmFrom 201 to 2000 ppm: ±5 % of the measured valueFrom 2001 to 8000 ppm: ±10 % of the measured value30 sNO Electrochemical From 0 to 5000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 5000 ppm: ±5 % of the measured value30 sLow range NO Electrochemical From 0 to 500 ppm 0.1 ppm From 0 to 100 ppm: ±2 ppmFrom 101 to 500 ppm: ±2 % of the measured value30 sNOx Calculated** From 0 to 5155 ppm 1 ppm – -NO2 Electrochemical From 0 to 1000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 1000 ppm: ±5 % of the measured value80 sSO2 Electrochemical From 0 to 5000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 5000 ppm: ±5 % of the measured value80 sCO2 Calculated** From 0 to 99 % vol 0.1% vol – -CH4 Semiconductor From 0 to 10000 ppmFrom 0 to 1 % VolFrom 0 to 20 %LEL1 ppm0.0001 % Vol0.002 %LEL±20 % of full scale 40 sFlue gas temperature K thermocouple From -100 to +1250 °C 0.1 °C ±0.4 % of the measured value or ±1.1 °C 45 sAmbient temperature Internal NTC From -20 to +120 °C 0.1 °C ±0.5 °CAmbient temperature Pt100 (1/3 DINexternal probe)From -50 to +250 °C 0.1 °C ±0.3 % of the measured value ±0.25 °C 30 sDew pointtemperatureCalculated** From 0 to +99 °Ctd 0.1 °C – -DHW temperature TcK (external probe) From -200 to +1300 °C 0.1 °C ±0.4 % of the measured value or ±1.1 °C -Draft Piezoelectric From -10 to +10 PaFrom -1000 to +1000 Pa0.1 Pa1 PaFrom -100 to -10 Pa: ±2 PaFrom -10 to +10 Pa: ±0.5 PaFrom +10 to +100 Pa: ±2 PaAbove: ±2 % of the measured value-Differential pressure Piezoelectric From -20 000to +20 000 Pa1 Pa From -20 000 to -751 Pa: ±0.5 % of the measured value ±4.5 PaFrom 750 to -61 Pa: ±0.9 % of the measured value ±1.5 PaFrom -60 to 60 Pa: ±2 PaFrom 61 to 750 Pa: ±0.9 % of the measured value ±1.5 PaFrom 751 to 20 000 Pa: ±0.5 % of the measured value ±4.5 Pa-Losses Calculated** From to 100% 0.1% – -Flue gas velocity Calculated** From to 99.9 m/s 0.1 m/s – -Excess air (λ) Calculated** From 1 to 9.99 0.01 – -Lower efficiency (ηs) Calculated** From 0 to 100% 0.1 % – -Higher efficiency (ηt)(condensation)Calculated** From 0 to 120% 0.1% – -Opacity index External instrument From 0 to 9 – – –
KEY POINTS
Built-in printer Intuitive interface due to icons LED on the probe handle to light dark areas Single connector Interchangeable probe 2 Go memory (100 000 measurements) Step by step procedure menu (gas flow, inspections)FEATURES OF THE INSTRUMENTGAS – Autozero in the flue- CO sensor protection bysolenoid valveFlue gas CO and ambientCO maxInterchangeable sensors: O2 long lifeand CO-H2 and NO and CH4 (optional)Excess airLossesEfficiency > 100%PRESSURE Differential pressuremeasurementDraft measurementTEMPERATURE Ambient temperature Flue gas temperature Delta Temperature DHW temperature2 thermocouplesDew pointtemperatureOTHERFUNCTIONS15 programmed combustibles1 Adding 5 combustibles bythe userOpacity indexCOMBUSTION GAS ANALYSERKIGAZ 210CO-H2, NO and CH4interchangeable sensorsCO sensor protection bysolenoid valveO2 long life sensor1Combustibles: Sahara/Fos-sur-Mer Natural Gas, Groningen Natural Gas, Russia/North Sea Natural Gas, Propane, LPG, Butane, Light Oil, Heavy Oil, Bituminous coal, Hard coal, Coke gas, Bio fuel 5 %,Wood 20 %, Wood-chip 21 %, Pellet 8 %Auto-zeroing in the flueKIGAZ MOBILE ApplicationMEASURING RANGEParameter Sensor Measuring range Resolution Accuracy*T90 responsetimeLong life O2 Electro-chemical From 0 % to 21 % 0.1 % vol. ±0.2 % vol. 30 sCO(with H2 compensation) Electro-chemical From 0 to 8000 ppm 1 ppmFrom 0 to 200 ppm: ±10 ppmFrom 201 to 2000 ppm: ±5% of measured valueFrom 2001 to 8000 ppm: ±10% of measured value30 sNO Electro-chemical From 0 to 5000 ppm 1 ppm From 0 to 100 ppm: ±5 ppm.From 101 to 5000 ppm: ±5% of measured value 30 sLow range NO Electrochemical From 0 to 500 ppm 0.1 ppm From 0 to 100 ppm: ±2 ppmFrom 101 to 500 ppm: ±2 % of the measured value 30 sNOx Calculated** From 0 to 5155 ppm 1 ppm – -CO2 Calculated** From 0 to 99 % vol 0.1 % vol – -CH4 SemiconductorFrom 0 to 10000 ppmFrom 0 to 1 % VolFrom 0 to 20 %LEL1 ppm0.0001 % Vol0.002 %LEL±20 % of full scale 40 sFlue gas temperature K thermocouple From -100 to +1250 °C 0.1 °C ±0.4 % of measured value or ±1.1 °C 45 sAmbient temperature Internal NTC From -20 to +120 °C 0.1 °C ±0.5 °CAmbient temperature Pt100 (1/3 DINexternal probe) From -50 to +250 °C 0.1 °C ±0.3 % of measured value ±0.25 °C 30 sDew pointtemperature Calculated** From 0 to +99 °Ctd 0.1 °C – -DHW temperature TcK (external probe) From -200 to +1300 °C 0.1 °C ±0.4 % of measured value or ±1.1 °C -Differential pressurePiezoelectricFrom -20 000to +20 000 Pa 1 Pa From -20 000 to -751 Pa: ±0.5 % of measured value ±4.5 PaFrom 750 to -61 Pa: ±0.9% of measured value ±1.5 PaFrom -60 to 60 Pa: ±2 PaFrom 61 to 750 Pa: ±0.9% of measured value ±1.5 PaFrom 751 to 20 000 Pa: ±0.5% of measured value ±4.5 Pa-Draft From -10 to +10 PaFrom -1000 to +1000 Pa0.1 Pa1 PaLosses Calculated** From 0 to 100% 0.1% – -Flue gas velocity Calculated** From 0 to 99.9 m/s 0.1 m/s – -Excess air (λ) Calculated** From 1 to 9.99 0.01 – -Efficiency (ηs) Calculated** From 0 to 100 % 0.1 % – -Efficiency (ηt)(condensation) Calculated** From 0 to 120 % 0.1 % – -Opacity index External instrument From 0 to 9 – -*All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions, or carried out with required compensation.**Calculation is made based on the measured values by the analyzer.
KEY POINTS 2 Go memory (100 000 measurements) Step by step procedure menu (gas flow, inspections) Self-test menu Built-in printerINSTRUMENT FEATURESGAS Ambient CO max Flue gas CO Interchangeable sensors: O2 longlife and CO compensated H2Excess airLossesEfficiency > 100%PRESSURE DraftmeasurementDifferential pressuremeasurementTEMPERATURE AmbienttemperatureFlue gas temperature Delta Temperature DHW temperature Dew point temperatureOTHERFUNCTIONS15 programmedcombustibles1Adding 5 combustiblesby the userOpacity index External watertrapCombustion gas analyserKIGAZ 1101Combustibles: Sahara/Fos-sur-Mer Natural Gas, Groningen Natural Gas, Russia/North Sea Natural Gas, Propane, LPG, Butane, Light Oil, Heavy Oil, Bituminous coal, Hard coal, Coke gas, Bio fuel 5%,Wood 20%, Wood-chip 21%, Pellet 8%DimensionsInstrument: 331 x 112 x 86 mmFlue gas probe: 180 mmCable length: 2.50 mWeight (battery and protectivecover included)1035 gDisplayLCD 120 x 160 pixels, 50 x 67 mmKeypad10-key dome switchkeypadMaterialHousing: ABSContact duct:PA 6.6 reinforced 10 %glass fiberProbe cable: neopreneProtectionIP40CommunicationUSBBluetooth® (option)Power supplyLi-Ion battery 3.6 V 4400 mAVoltage of power supply:100-250 VAC, 50/60 HzBattery life10 h in continuous operatingBattery charging time10 hOperating and storage temperatureFrom +5 to +50 °Cand from -20 to +50 °CAltitude: from 0 to 2000 mO2 long life sensorCO-H2 interchangeable sensorKIGAZ MOBILE ApplicationSensor protection by pump stopping
MEASURING RANGEParameter Sensor Measuring range Resolution Accuracy* T90 response timeO2 Electro-chemical From 0 % to 21 % 0.1 % vol. ±0.2 % vol. 30 sCO(with H2 compensation) Electro-chemical From 0 to 8000 ppm 1 ppmFrom 0 to 200 ppm: ±10 ppmFrom 201 to 2000 ppm: ±5% of measured valueFrom 2001 to 8000 ppm: ±10% of measured value30 sFlue gas temperature K thermocouple From -100 to +1250 °C 0.1 °C ±0.4% of measured value or ±1.1 °C 45 sAmbient temperature Internal NTC From -20 to +120 °C 0.1 °C ±0.5 °C -Ambient temperature Pt100 (external probe1/3 DIN) From -50 to +250 °C 0.1 °C ±0.3% of measured value or ±0.25 °C 30 sDew-point temperature Calculated** From 0 to +99 °Ctd 0.1 °C – -DHW temperature TcK (external probe) From -200 to +1300 °C 0.1 °C ±0.4% of measured value or ±1.1 °C -Differential pressureSemiconductorFrom -20 000 to+20 000 Pa 1 Pa From -20 000 to -751 Pa: ±0.5 % of measured value ±4.5 PaFrom -750 to -61 Pa: ±0.9 % of measured value ±1.5 PaFrom -60 to 60 Pa: ±2 PaFrom 61 to 750 Pa: ±0.9 % of measured value ±1.5 PaFrom 751 to 20 000 Pa: ±0.5 % of measured value + 4.5 PaDraft From -10 to +10 Pa -From -1000 to +1000 Pa0.1 Pa1 PaLosses Calculated** From 0 to 100 % 0.1 % – -Excess air (λ) Calculated** From 1 to 9.99 0.01 – -Lower efficiency (ηs) Calculated** From 0 to 100 % 0.1 % – -Higher efficiency (ηt)(condensing) Calculated** From 0 to 120 % 0.1 % – -Opacity index External instrument From 0 to 9 – – -*All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions, or carried out with required compensation.**Calculation is made based on the measured values by the analyser.