Digital HVAC Instruments

hvac-portable-instruments-250x250

Portable Manometers & Anemometers

We offer a wide assortment of Portable Manometers & Anemometers at industry leading price. These devices are widely appreciated for their efficiency and durability. We are one of the leading manufacturer of portable manometers & anemometers these are manufactured from quality material and are easily available at very reasonable price.

Specifications:

  • Current/voltage: 0 to 2.5v, 0 to 10v and 0 to 4-20mA
  • Climatic conditions: -20 to +80°c, 5 to 95%Rh and 800 to 1,100hPa
  • Power supply: 18 to 30VDC, 24VAC/VDC

temperature-sensors-master-booklet-250x250

 Temperature Probes

These Temperature Probes are manufactured from quality material, with cost effective method. These are known for their competitive price, reliability and durability all over the world. Our temperature probes are highly in demand in market. These probes are ready to work in heavy work environment.

Specifications:

  • Temperature: -50 to +400 °C
  • Output: 4 to 20 mA or 0 to 10 V
  • Bracket: Stainless Steel

temperature-probes-complete-range-250x250

Temperature Probes

We offer complete range of Temperature Probes for different application areas. This range of temperature probes are highly appreciated for their accuracy and durability. Our products find their application in research and development lab, chemical, food and pharmaceutical industries. They are made of superior quality raw materials and we offer them at industry leading prices.

Specifications:

  • Temperature: -50 to +400oc
  • Length: 1000 to 2000mm
  • Output: 0 to 10 v/4-20mA

ex-explosion-proof-at-ex-sil-applications-250x250

 Explosion Proof Instruments

We offer a diversified range of Explosion Proof Instruments for different application areas. This range includes all electrical devices and protective systems used to minimize the effect of explosion. It includes controllers, single and binary sensors, transducer, actuators and similar devices. We manufacture these devices by high quality raw materials and sophisticated machinery. These devices are fully certified and approved from inspection companies.

Specifications:

  • Dimensions (H×W×D): 177×107×66mm
  • Power: 24 VAC/DC
  • Speed control range: 50 to 10.000min-1

explosion-proof-instruments-250x250

Explosion Proof Instruments

We offer a wide range of Explosion Proof Instruments, these are manufactured from quality material, and are easily available at very reasonable price. Client satisfaction is our main motive, keeping this in mind we manufacture world class explosion proof instrument. These are known for their reliability, durability etc.

Specifications:

  • Power supply: 24 to 240v AC/DC
  • Dimensions: (H×W×D) 210×95×80 mm
  • Shaft connection: 12×12 mm

digital-portable-manometers-250x250

Digital Portable Manometers

We offer unique quality Digital Portable Manometers at industry leading price. These devices are manually operated. Kimo HVAC Instruments have a full range for all HVAC applications and for all applications which require precise measurements of pressure. Some interesting features of this product are the digital display with programming key pad. Soft ware analysis can be provided as a total solution for all customers.

Specifications:

  • Overpressure allowed: MP 100:250 m bar, MP 101:700 m bar
  • Display: 2 lines, LCD technology
  • Sizes: 50×34.9 mm
  • Keypad: Metal-coated with 5 keys
  • Operating temperature: 0 to 50°c
  • Storage temperature: -20 to +80°c
  • Weight: 190 gm
  • Languages: French, English
  • Keypad: Metal-coated with 5 keys

digital-sound-noise-and-db-meters-250x250

 Sound Level Meter

We offer a wide assortment of Sound Level Meter for industrial applications. Digital Sound, noise and DB meters, are fully digital sound meters used for sound monitoring. One can monitor the noise or sound level generated in a factory, airport or hotel to meet the international standards of noise pollution and sound levels generated by large machines. Our sound meters allow data storage and measurements. We offer these meters at industry leading prices.

Specifications:

  • Analogue output: 0-10VDC
  • Humidity: 0 to 90%hr
  • Dimensions: 270x70x40 mm
  • Weight: 280 gm
  • Screen: Graphic display 240×160 pixels
  • Keypad: 8 sensitive keys

co-carbon-monoxide-detector-250x250

CO Carbon Monoxide Detector Class 50

CO Carbon Monoxide Detector
Hand Held Portable.
Key Point

Easy to use

HOLD function

Built-in probe

Auto shut-off : 20 minutes

Feature of the Housing

71.5 mm

147.9 mm

34.2 mm

26 mm

110 mm

Material :

Protection :

 

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

Parameter Temperature

Measuringunits
Measuring Range
Accuracy*
Resolution
Response time
Measuring elements
Operating temperature
Storage temperature
Power supply
Battery life
Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

200 hours

4 batteries AAA LR03 1.5 V

From -20 to +80 °C

From 0 to +50 °C

NTC Electrochemical sensor

T63 = 5 s T63 = 35 s

0.1 °C 0.1 ppm

±0.4% of reading ±0.3°C From 0 to 100 ppm : ±3 ppm

From100 to 500 ppm : ±3% of reading

From -20 to +80 °C From 0 to 500 ppm°C, °F ppm

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS

tachometer-250x250

 Tachometer CT50 Class 50

achometer CT 50
Class 50.

Key Point

Easy to use

HOLD function

Built-in probe

Auto shut-off : 20 minutes

Feature of the Housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

Parameter Optical velocity Contact velocity

Measuring units

Measuring Range

Accuracy*

Resolution

Measuring elements

Operating temperature

Storage temperature

Power supply

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

20 hours

4 batteries AAA LR03 1.5 V

From -20 to +80 °C

From 0 to +50 °C

Photo transistor, sighting distance

max. 40cm

ETC Adapter positioned on optical probe 1 rpm 1 rpm

From 60 to 10 000 rpm : ±0,3 % of reading ± 1 rpm

From 10 001 to 60 000 : ±30 rpm From 30 to 20 000 rpm : ±1 % of reading

±1 rpm

From 0 to 60 000 rpm From 0 to 20 000 rpm

rpm rpm, m/min, ft/min, in/min, m/s

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS

thermo-hygrometer-hd-50-250x250

Thermo Hygrometer HD 50

Thermo Hygrometer
Temperature and Humidity
Class 50 Hand Portable.

Key Point

Easy to use

Hold function

Built-in probe

Auto shut-off : 20 minutes

Feature of the Housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

1

34.2 mm

13 mm

48 mm

71.5 mm

147.9 mm

Parameter Temperature Hygrometry

Measuring Units

Measuring range

Accuracy: 1

Uncertainty adjustment in factory:

Drift linked to the temperature:±0.04 x (T-20) %HR (if T<15°C or T>25°C)

Resolution

Response time

Operating temperature

Storage temperature

Measuring element

Power supply

Battery life

Conformity

 

Directives CEM 2004/108/CE and NF EN 61010-1

100 hours

4 batteries AAA LR03 1.5 V

Digital sensor CMOS

From -20 to +70 °C

From -10 to +50 °C

T63 = 5 s T63 = 4 s

0.1 °C 0.1%HR

±0.88

%HR

 

±0.4% of reading ±0.3°C

Accuracy* (Repeatability, linearity,

hysteresis)

: ±1.8%HR (from 15°C to 25°C)

From -20 to +70 °C From 5 to 95%RH

°C, °F %RH

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation

*In accordance with NFX 15-113 and the charter 2000/2001 Hygrometers, GAL (guarantee accuracy limit) which has been calculated with a coverage factor value of 2 is ±2,68 % RH between 15 and 25°C on the measuring range from 3 % to

98 %HR. The sensor drift is less than 1 % RH/year.

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS

thermo-anemometer-vane-properllor-class-50-250x250 (1)

Thermo Anemometer Vane Properllor Class 50

Propeller Thermo-anemometer
Lv 50
Key Points
Easy To Use
Hold Function
Built-in Propeller
Auto Shut-off : 20 Minutes
Features Of The Housing
Material :
Protection :
Display :
Height Of Digits :
Values : 9. 2 Mm
Units : 4. 7 Mm
Diameter Of The Propeller :
Weight :
Technical Features
*
All The Accuracies Indicated In This Technical Datasheet Were Stated In Laboratory Conditions, And Can Be Guaranteed For Measurements Carried Out In The Same Conditions, Or Carried Out With Calibration Compensation
.
Ø 106. 1 Mm
106. 1 Mm
147. 9 Mm 145. 4 Mm
71. 5 Mm
45 Mm
34. 2 Mm
45 Mm
Parameter Temperature Velocity
Measuring Units
Measuring Range
Accuracy*
Resolution
Response Time
Measuring Elements
Operating Temperature
Storage Temperature
Power Supply
Battery Life
Conformity
Directives Cem 2004/108/ce And Nf En 61010-1
70 Hours
4 Batteries Aaa Lr03 1. 5 V
From -20 To +80 °c
From 0 To +50 °c
Ctn Hall Effect Sensor
T63 = 5 S T63 = 4 S
0. 1 °c From 0. 3 To 3 M/s : 0. 01 M/s
From 3. 1 To 35 M/s : 0. 1 M/s
±0. 4% Of Reading ±0. 3°c From 0. 3 To 3 M/s : ±3% Of Reading ±0. 1 M/s
From 3. 1 To 35 M/s : ±1% Of Reading ±0. 3 M/s
From -20 To +80 °c From 0. 3 To 35 M/s
°c, °f M/s, Fpm, Km/h
200 G (with Batteries)
100 Mm
1 Line
Lcd 1 X 5 Digits
Size : 50 X 20 Mm
Ip54
Abs

lux-meter-lx50-class-50-250x250

LUX Meter LX50 Class 50

Lux meter

LX 50

Key Point

Easy to use

HOLD function

Built-in probe

Auto shut-off : 20 minutes

Feature of the Housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation.

71.5 mm

147.9 mm

34.2 mm

46 mm

45.1 mm

19 mm

22 mm

23.3 mm

Parameter Light

Measuring units

Measuring range

Accuracy

Resolution

Measuring element

Spectral range

Estimation of uncertainty on V(λ) (f1)

Directional sensitivity (f2)

Linearity

Operating temperature

Storage temperature

Power supply

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

20 hours

4 batteries AAA LR03 1.5 V

From -10 to +70 °C

From 0 to +50 °C

<3%

<6%

<10%

In accordance with the standard photopic curve V (λ) NF C 42-710 class C

Silicon Photodiode

From 0 to 999.9 lux : 0.1 lux / from 1000 to 10000 lux : 1 lux

From 0 to 0.9999 klux : 0.0001 klux / from 1 to 10 klux : 0.001 klux

From 0 to 99.99 fc : 0.01 fc / from 100 to 929 fc : 0.1 fc±3% of reading ±3 lux

From 0 to 10000 lux / From 0 to 10 klux

From 0 to 929 fclux, klux, fc

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS

mp50-250x250

Manometer MP 50 51 Portable Hand Held

Manometer

MP 50 – MP 51

KEY POINTS

Easy to use

HOLD function

Auto shut-off : 20 minutes

Manual auto zero

Feature of the Housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation.

71.5 mm

147.9 mm

34.2 mm

22 mm

8.6 mm

6.2 mm

Parameter MP50 MP51

Measuring units

Measuring range

Accuracy*

Resolution: 2O

Response time

Operating temperature

Storage temperature

Measuring element

Power supply

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

180 hours

4 batteries AAA LR03 1.5 V

Piezoresistive sensor

From -20 to +80 °C

From 0 to +50 °C

T63 = 0.3 s

1 Pa From -200 to +200 mmH2O : 0.1 mmH2 O

Beyond : 1 mmH

±0.5% of reading ±2 Pa ±0.5% of reading ±2 mmH2 O From -1000 to +1000 Pa From -1000 to +1000 mmH2 OPa, mmH2O, inWg, daPa mmH2

O, k Pa, in Wg, m bar, mm Hg, daPa

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS

mp55-barometer-250x250

Barometer Atmospheric Atmosphere Pressure

Atmospheric pressure

MP 55

KEY POINTS

Easy to use

HOLD function

Built-in probe

Autozero : 20 minutes

Feature of the housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Specification

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation.

14.1 mm

6.2 mm

71.5 mm

147.9 mm

34.2 mm

Parameter MP55

Velocity

Measuring units

Measuring range

Accuracy*

Resolution

Response time

Measuring elements

Operating temperature

Storage temperature

Power supply

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

180 hours

4 batteries AAA LR03 1.5 V

Piezo resistive sensor

From -20 to +80 °C

From 0 to +50 °C

Barbed connectors, Ø6.2 mm made of nickelled brass

T63 < 10 s

0.1 mbar / 0.1 mm Hg / 0.1 h Pa ±2 m bar

From 700 to 1100 m bar

mbar, mm Hg, h Pa

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS

tk-50-250x250

Thermometer TK50

Thermometer

TR 50 – TR 52

2 Channel Thermometer.

KEY POINTS

Easy to use

HOLD function

Detachable probe

Auto shut-off : 20 minutes

FEATURES OF THE HOUSING

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

TECHNICAL FEATURES

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation

71.5 mm

147.9 mm

34.2 mm

76.7 mm

TR 50

76.7 mm

TR 52

Parameter Temperature

Measuring units

Measuring range

Accuracy*

Resolution

Channels number

Response time

Measuring element

Operating temperature

Storage temperature

Power supply

 

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

180 hours

4 batteries AAA LR03 1.5 V

From -20 to +80 °C

From 0 to +50 °C

Pt100 Class A

T63 = 5 s

TR50 : 1 channel

TR52 : 2 channels

0.1 °C

±0.4% of reading ±0.3°C

From -100 to +400 °C

°C, °F

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS

hot-wire-250x250

Hot Wire Thermo Anemometer Portable

Hotwire Thermo-anemometer

VT 50

KEY POINTS

Easy to use

HOLD function

Hotwire probe

Auto shut-off : 20 minutes

Feature of the Housing

Material :

Protection :

Display :

Height of digits :

Values : 9.2 mm

Units : 4.7 mm

Weight :

Technical Feature

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation

Parameter Temperature

Velocity

Measuring units

Measuring range

Accuracy*

Resolution

Response time

Measuring elements

Operating temperature

Storage temperature

Power supply

Battery life

Conformity

Directives CEM 2004/108/CE and NF EN 61010-1

40 hours

4 batteries AAA LR03 1.5 V

From -20 to +80 °C

From 0 to +50 °C

NTC Thermistor with a negative temperature coefficient

T90 = 1 s for Vair

= 1 m/s T63 = 6 s

0.1 °C From 0 to 3 m/s : 0.01 m/s

From 3 to 30 m/s : 0.1 m/s

±0.3% of reading ±0.25°C From 0.15 to 3 m/s : ±3% of reading ±0.05 m/s

From 3.1 to 30 m/s : ±3% of reading ±0.2 m/s

 

From -20 to +80 °C From 0.15 to 30 m/s

°C, °F m/s, fpm, km/h

200 g (with batteries)

1 line

LCD 1 x 5 digits

Size : 50 x 20 mm

IP54

ABS

df110-250x250

DF110 Refrigeration Gas and Hydrogen Detector

=DF 110

Detector of refrigirant gases and

hydrogen (H2

) Gas Detector.

KEY POINTS

TECHNICAL FEATURES

HCFC :

R22

R134a, R404a, R407c, R410a, R32, R422a/b/c/d,

R425a, R507a, R125

CFC :

Others : H2

Indication

Probe

Autonomy

Housing

Keypad

Conformity

Power supply

Ambiance

Operating temperature

Storage temperature

Auto-extinction

Weight

REGLE MENTATIONS

The refrigerant gas detector complied with the EN 14624 standard that

determines the following points : – Fixed and on the go minimum

threshold of sensitivity : 1 g/year

(minimum)

– Minimum time of detection (1g/an) :

– Detection of mixtures 5% hydrogen – 95% nitrogen (Nidron 5…)

– Heated diode sensor

– 3 modes of sensitivity (high, low and normal)

– Manual and automatic autozero

Specification

Mode Indicative measuring range (g/an)

Visual alarm

Low sensitivity ( “B” on the device)

From 0 to 300 g/an All the leds (8) for 300g/an

Normal sensitivity (“Norm” on the device)

From 0 to 30 g/an All the leds (8) for 30 g/an

High sensitivity (“H” on the device)

From 0 to 3 g/an All the leds (8) for 3 g/an

Verification

Certificate*

*According to the decree number 2007-737

1 second
– Detection of all the HCFC and HFC refrigerants

295 g

15 min

From -20 to +80 °C

From 0 to +50 °C

Neutral gas

4 AAA LR03 1.5 V batteries

EMC 2004/108/CE and EN 61010-1 Directives

3 keys

Anti-choc ABS, protection IP54

> 12 hours

Flexible, 400 mm length

LED : gradual lighting up when the gas concentration increases

Audible : the beep frequency increases when the gas concentration increases

, R290, R600a, HFO-1234yf

R12 et R502

gas-leak-250x250 (1)

 

Gas Leak Detector Hand Portable

Gas leak detector

FG 110

Detection of gas such as methane(CH4 ), LPG ( isopropanol and isobutane) and others combustible gas (hydrocarbons).

Hold function

Alarm (from 1000 to 10000 ppm)

Display of minimum and

maximum values

Configurable auto shut-off

Backlight

 

KEY POINTS

– Hold-min-max function

– Adjustable back-light

FUNCTIONS

Detection of gas such as methane

(CH4), LPG ( isopropanol and

isobutane) and others combustible

gas (hydrocarbons)

Hold function

Alarm (from 1000 to 10000 ppm)

Display of minimum and

maximum values

Configurable auto shut-off

Backlight

TECHNICAL FEATURES

Measuring element

Display

Probe

Housing

Keypad

Conformity

Power supply

Autonomy

Ambience

Operating temperature

Storage temperature

Auto shut-off

Weight

– Easy to use

– Indication of gas leaking in ppm, %vol

or %LEL

SPECIFICATIONS

1.All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out

with calibration compensation

%LEL :

%VOL :

is the limiting concentrations of gas (in air) that is needed for the gas to ignite and

explode expressed in percentage of volume in air.

is the limiting concentrations of gas (in air) that is needed for the gas to ignite and

explode.

295 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral Gas

20 houres

4 batteries AAA LR03 1.5 V

Directives CEM 2004/108/CE and NF EN 61010-1

5 keys

ABS, protection IP54

Flexible, 330 mm

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

semiconductor sensor

air-quality-portable-250x250

Air Quality Portable AQ 110

  • Air qualityAQ 110KEY POINTS- Selection of units- Adjustable backlightFUNCTIONSSelection of temperature unitsHold function
  • Display of minimum andmaximum valuesConfigurable Auto shut-off
  • Backlight- Easy to use- hold-min-max FunctionSPECIFICATIONSTECHNICAL FEATURESMeasuring elements CO2 :Temperature :DisplayCableHousingKeypadConformityPower supplyBattery life
  • AmbienceOperating temperatureStorage temperatureAuto shut-offWeightMeasuring units Measuring range Accuracy1.Resolution2.COppm From 0 to 5000 ppm ±3 % of reading ±50 ppm 1 ppmTemperature°C, °F From – 20 to +80°C ±0.4% of reading ±0.3°C 0.1°C*Except class 110 SMAINTENANCESUPPLIED WITHInstruments are supplied with :

    Calibration certificate*

    Transport case

    ACCESSORIES

    CQ 15 :

    RTE :2

    concentration.

    Non dispersive infrared absorbance

    Infrared light Gas sample

    Wavelength Wavelength

    Infrared sensor

    OPERATING PRINCIPLES

    DIMENSIONS

    71.5 mm

    147.9 mm

    34.2 mm

    76.7 mm

    MT 51 :

    Thermometer : CTN Probe

    Negative temperature coefficient probes are thermistors with a resistance that

    decreases with temperature according to the equation below:.

    RT= resistance sensor value at temperature T

    R(T

    0)= resistance sensor value at reference temperature T

    0

    T and T

    0

    in °C

    and T0

    sensor specific constants

    ABS Transport

    case

    Telescopic extension, length

    1m, with index at ±90°

    All the gases absorbs the light at a specific wavelength, a part of the light emitted by the

    infra-red source is absorbed by the gas sample. The quantity of light read by the infrared

    sensor is inversely proportional to the CO

    Magnetic protective

    housing

    340 g

    Adjustable from 0 to 120 min

    From -20 to +80 °C

    From 0 to +50 °C

    Neutral gas

    20 hours

    4 batteries AAA LR03 1.5 V

    Directives EMC 2004/108/CE and EN 61010-1

    5 keys

    ABS, protection IP54

    Retractable, length. 0.45 m, extension : 2.4 m

    4 lines, LCD technology. Sizes 50 x 36 mm

    2 lines of 5 digits with 7 segments (value)

    2 lines of 5 digits with 16 segments (unit)

    NTC

    infrared sensor

    to 30VDC, 24VAC/VDC

co110-250x250

CO Carbo Monoxide Portable

CO meter

CO 110

KEY POINTS

Easy to use

– Adjustable backlight

FUNCTIONS

CO maximum

2 configurable alarms

Selection of temperature units

Hold function

Display of minimum and maximum

values

Adjustable and reseatable Auto

shut-off

Backlight

CO max display

– Two configurable alarm thresholds

SPECIFICATIONS

Measuring units Measuring range Accuracy

1.Resolution

CO

ppm

From 0 to 100 ppm

From 100 to 500 ppm

±3 ppm

±3 % of reading

0,1 ppm

Ambient temperature

°C, °F From – 20 to +80 °C ±0.4% of reading

±0.3°C

0,1°C

TECHNICALS FEATURES

Measuring elements CO :

Température :

Display

Cable

Housing

Keypad

Conformity

Power supply

Battery life

Ambience

Operating temperature

Storage temperature

Auto shut-off

Weight

1

*Except class 110 S

OPERATING PRINCIPLES

Electrochimical sensor

OH

-, HCO A

3, CO

3

2-

Gas

Air

Working electrode

Backing electrode

Alkaline

Electrolytes

Thermometer : NTC probe

Negative temperature coefficient probes are thermistors with a resistance that decreases

with temperature according to the equation below:

RT= resistance sensor value at temperature T

R(T0)= resistance sensor value at reference

All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or

carried out with calibration compensation

310 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral Gas

200 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

5 keys

ABS, protection IP54

Retractable, lenght. 0.45 m, extension : 2.4 m

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

NTC

electrochemical sensor

co110-250x250

 CT 110 Tachometer Portable Class 110

Tachometer

CT 110

KEY POINTS

-Easy to use

– Adjustable backlight

– contact/optical selection

FUNCTIONS

Contact / optical selection

Selection of tachometer units

Hold function

Display of minimum and maximum

values

Configurable auto shut-off

Backlight

– hold-min-max function

– Selection of units

TECHNICAL FEATURES

Measuring elements Optical tachometry :

Contact tachometry :

Display

Cable

Housing

Keypad

Conformity

Power supply

Ambience

Température d’utilisation

Température de stockage

Auto shut-off

Weight

SPECIFICATIONS

Measuring units Measuring range Accuracy

1.Resolution

Optical tachometer

rpm From 0 to 60 000

rpm

From 60 to 10 000 rpm : ± 0,3 % of

reading ± 1 rpm

From 10 001 to 60 000 RPM : ±30

1 rpm

Contact tachometer

rpm, m/min,

ft/min, in/min, m/s

From 0 to 20 000

rpm

From 30 to 20 000 rpm: ± 1 % of

reading ± 1 rpm

1 rpm

*All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with

calibration compensation

*Except class 110 S

OPERATING PRINCIPLES

Contact tachometry

Disk in rotation

Probe in rotation

Frequency =

disk velocity

No reflection= No signal

Mirror in rotation

Lightbeam

Reflected

beam

Lightsensitive

cell

Reflection=si

gnal

Optical tachometry

DIMENSIONS

MAINTENANCE

SUPPLIED WITH

Instruments are supplied with :

Optical tachometry probe Ø 17 mm,

length. 195 mm

Tip of contact tachometry

A reflective tape

Calibration certificate*

Transport case (ref : ST 110)

ACCESSORIES

RTE :

GUARANTEE

MT 51 :

71.5 mm

147.9 mm

34.2 mm

76.7 mm

Ø40 mm

60 mm

30 mm

CQ 15 :

Magnetic protective

housing

ABS

transport case

Telescopic extension,

length 1m, with index at ±90°

190 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral Gas

4 batteries AAA LR03 1.5 V

Directives EM C 2004/108/CE and EN 61010-1

5 keys

ABS, protection IP54

Coiled, length. 0.45m, extension : 2.4 m

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

ETC adaptator for optical

tachometry probe

optical detection

(Phototransistor sighting distance max. 40 cm)

gas-leak-250x250 (1)

FG 110 Gas Leak Detector Methane LPG Gases

Gas leak detector

FG 110

KEY POINTS

– Hold-min-max function

– Adjustable back-light

FUNCTIONS

Detection of gas such as methane

(CH4), LPG ( isopropanol anisobutane) and others combustible

gas (hydrocarbons)

Hold function

Alarm (from 1000 to 10000 ppm)

Display of minimum and

maximum values

Configurable auto shut-off

Backlight

TECHNICAL FEATURES

Measuring element

semiconductor sensor

Display

Probe

Housing

Keypad

Conformity

Power supply

Autonomy

Ambience

Operating temperature

Storage temperature

Auto shut-off

Weight

-Easy to use

– Indication of gas leaking in ppm, %vol

or %LEL

SPECIFICATIONS

1.All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out

with calibration compensation

%LEL :

%VOL :

is the limiting concentrations of gas (in air) that is needed for

is the limiting concentrations of gas (in air) that is needed for the gas to ignite and

explode.

295 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral Gas

20 houres

4 batteries AAA LR03 1.5 V

Directives CEM 2004/108/CE and NF EN 61010-1

5 keys

ABS, protection IP54

Flexible, 330 mm

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

hd-110-portable-thermo-hygrometer-class-110-250x250

 

HD 110 Portable Thermo Hygrometer Class 110

Thermo-hygrometer

HD 110

KEY POINTS

-Easy to use

– Adjustable blacklight

– Hold-min-max functions

– Selection of unit

easuring element

Digital sensor (CMOS)

Display

Cable

Housing

Keypad

Conformity

Power supply

Battery life

Ambiance

Operating temperature (instrument)

Operating temperature (probe)

Storage temperature

Auto shut-off

Weight

Thermo-hygrometer

HD 110

KEY POINTS

-Easy to use

– Adjustable blacklight

– Hold-min-max functions

– Selection of units

FUNCTIONS

Relative humidity, dew point and

temperature measurements

Selection of units (temperature anddew point)

Hold Function

Display of minimum and maximum

values

Adjustable and reseatable auto shutoff

Backlight

SPECIFICATIONS

Measuring units Measuring range Accuracy

1.Resolution

Relative humidity

%HR From 5 to 95

%HR

Accuracy* (Repetability, linearity, hysteresys) :

±1,8 %HR (from 15 °C to 25 °C)

Factory calibration uncertainty :

Drift linked to the temperature :

0,1 %HR

Dew point

°C

td, °F

td

From -40 to +70

°C

td

±0.8% of reading ±0.6°C

td 0,1 °C

td

Ambient temperature

°C, °F From -20 to +70

°C ±0.4% of reading ±0.3°C 0,1 °C

*All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out in the same conditions, or carried out with required compensation.

As per NFX 15-113 and the Charter 2000/2001 HYGROMETERS, GAL (Guaranteed Accuracy Limit) which has been calculated with a coverage factor value of 2 is ±2.68%RH between 15 and 25°C

on the measuring range from 5 to 95%RH. Sensor drift is less than 1%RH/year.

*Except class 110 S

±0,04 x (T-20)

%HR

(fi T < 15°C or T > 25°C)

±0,88 %HR

310 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From -20 to +70 °C

From -10 to +50 °C

Neutral gas

150 hours

4 batteries AAA LR03 1.5 V

Directives CEM 2004/108/CE and NF EN 61010-1

5 keys

ABS, protection IP54

Coiled, length 0.45 m, expanding to 2.4 m

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (units)

lv110-250x250

Vane Probe Thermo Anemometer LV110 Class

Vane probe thermo-anemometer

LV 110 – LV 111 – LV 117

KEY POINTS

– Airflow calculation

– Automatic average

FUNCTIONS

Airflow calculation

Airflow calculation with cone (LV 110/117)

Automatic average

Selection of units (air velocity, airflow and

temperature)

Hold function

Display of minimum and maximum values

Configurable auto shut-off

Backlight

Detection of flow direction (LV 110/117)

Selection of the type of cone

Dimensions of rectangular and circular

duct

– Hold-min-max function

– Selection of units

TECHNICAL FEATURES

Measuring elements Air velocity :

Ambient temperature :

Display

Vane probe diameter LV111 :

LV110 :

Cable

Housing

Keypad

Conformity

Power supply

Battery life

Ambience

Operating temperature (instrument)

Operating temperature (probe)

Storage temperature

Auto shut-off

Weight

SPECIFICATIONS

Models Measuring

units

Measuring

range

Accuracy

1.Resolution

Air velocity

LV111 : Ø 14 mm m/s, fpm, km/h From 0.8 to 25 m/s

From 0.8 to 3 m/s : ±3% of

reading ±0.1 m/s

From 3.1 to 25 m/s : ±1% of

reading ±0.3 m/s

0.1 m/s

LV110 : Ø 100 mm m/s, fpm, km/h From 0.3 to 35 m/s

From 0.3 to 3 m/s : ±3% of

reading ±0.1 m/s

From 3.1 to 35 m/s : ±1% of

reading ±0.3 m/s

0.01 m/s

0.1 m/s

LV117 : Ø 70 mm m/s, fpm, km/h From 0.4 0 to 35

m/s

From 0.4 to 3 m/s : ±3% of

reading ±0.1 m/s

From 3.1 to 35 m/s : ±1% of

reading ±0.3 m/s

0.1 m/s

Airflow

All models m³/h, cfm, l/s,

m³/s

From 0 to 99 999

m³/h

±3% of reading ±0.03 *

area (cm²) 1 m³/h

Temperature

All models °C, °F From -20 to +80 °C ±0.4 % of reading ±0.3 °C 0.1 °C

390 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

From 0 to +50 °C

Neutral gas

120 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

5 keys

ABS, protection IP54

Coiled, lg. 0.45 m, extension : 2.4 m

Ø 100 mm

Ø 14 mm / LV117 :

Ø 70 mm

4 lines, LCD technology. Sizes 50 x 36 mm

2 lines of 5 digits with 7 segments (value)

2 lines de 5 digits with 16 segments (unit)

NTC sensor

Hall effect sensor

mp110-1-250x250

Manometer Digital Portable MP Class 110

Manometer

MP 110 – MP 111

MP 115 – MP 112

KEY POINTS

– Easy to use

– Adjustable backlight

– Hold-min-max function

FUNCTIONS

Pressure measurement

Selection of units

Manual autozero

Hold function

Display of minimum and maximum

values

Configurable Auto shut-off

Backlight

– Selection of units

– Manual autozero

TECHNICAL FEATURES

Measuring elements

Tolerated overpressure

Connector

Display

Housing

Keypad

Conformity

Power supply

Autonomy

Ambience

Operating temperature

Storage temperature

Auto shut-off

Weight

PRESSURE SPECIFICATIONS

Models Measuring

units

Measuring

range

Accuracy

1.Resolution

MP 110

Pa, mmH

2

O

inWg, daPa

From -1000 to

+1000 Pa ±0.5% of reading ±2 Pa 1 Pa

MP 111

Kpa, mmH

2

O,

inWg, mbar,

mmHg, daPa

From -1000 to

+1000 mmH

2

O

±0.5% of reading ±2

mmH

2

O

De 0 à ±200 mmH

2

O: 0,1 mmH

2

O

Au delà : 1 mmH

2

O

MP 115 kPa, inWg, mbar,

mmHg, PSI

From -500 to

+500 mbar

±0.5% of reading ±0.5

mbar 0.1 mbar

MP 112 kPa, inWg, mbar,

mmHg, PSI, bar

From -2000 to

+2000 mbar ±0.5% of reading ±2 mbar 1 mbar

1.All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out

220 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral gas

180 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

5 keys

ABS, protection IP54

4 lines, LCD technology. Sizes 50 x 36 mm.

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

MP 110 / 111 : Ø 6.2 mm barbed connectors made of nickelled brass

MP 115 / 112 : Ø 4.6 mm threaded connectors of nickelled brass

MP 110 : 250 mbar / MP 111 : 700 mbar

MP 115 : 1.4 bar / MP 112 : 3 bar

Piezoresistive sensor

thermometer-250x250

 

Thermocouple Thermometers

Thermocouple thermometers

TK 110 – TK 112

KEY POINTS

-Adjustable alarms

– Adjustable backlight

FUNCTIONS

Selection of temperature units

Adjustable alarms

Hold function

Display of minimum and maximum

values

Configurable auto shut-off

Backlight

Delta temperature (TK112)

-Hold-min-max functions

– Selection of units

TECHNICAL FEATURES

Measuring elements

Channels number

Display

Boîtier

Clavier

Connector engineering

Conformité

Power supply

Battery life

Ambience

Operating temperature

Storage temperature

Auto shut-off

Weight

SPECIFICATIONS

1.All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for measurements carried out with required

compensation.

* The accuracy is expressed either by a deviation in °C, or by a percentage of the value concerned. Only the bigger value is considered.

Models Measuring units Measuring range Accuracy

1.Resolution

Thermocouple probes(see related data sheet)

Thermocouple

K °C, °F From -200 to +1300 °C ±1.1 °C or ±0.4%

of reading value* 0.1 °C

Thermocouple

J °C, °F From -100 to +750 °C ±0.8 °C or ±0.4%

of reading value* 0.1 °C

Thermocouple

T °C, °F From -200 to +400 °C ±0.5 °C or ±0.4%

of reading value* 0.1 °C

Thermocouple

S °C, °F From 0 to 1760 °C ±1 °C or ±0.4%

of reading value* 0.1 °C

210 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral Gas

180 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

Compensated miniature female connectors

5 keys

ABS, protection IP54

4 lines, LCD technology. Sizes 50 x 36 mm.

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

TK110 : 1 channel

TK112 : 2 channels

Thermocouple K, J, T ou S

tr110-250x250

 Pt 100 Thermometer Digital Portable TR110

Pt100 Thermometer

TR 110 – TR 112

KEY POINTS

– Adjustable alarms

– Adjustable backlight

FUNCTIONS

Selection of temperature units

Adjustable alarms

Hold function

Display of minimum and maximum

values

Configurable auto shut-off

Backlight

Delta temperature (TR112)

– Hold-min-max function

– Selection of units

TECHNICAL FEATURES

Measuring element

Number of channels

Display

Housing

Keypad

Connector

Conformity

Power supply

Battery life

Ambience

Operating temperature

Storage temperature

Auto shut-off

Weight

SPECIFICATIONS

Measuring units Measuring range Accuracy

1 Resolution

Pt100 probes (see related data sheet)

°C, °F From -100 to +400 °C ±0.4% of reading ±0.3°C 0.1 °C

210 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

Neutral gas

180 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

Compensated miniature female connectors

5 keys

ABS, protection IP54

4 lines, LCD technology. Sizes 50 x 36 mm.

2 lines of 5 digits with 7 segments (value)

2 lines of 5 digits with 16 segments (unit)

TR110 : 1 channel

TR112 : 2 channels

Pt100 class A

vt110-2-250x250

Hot Wire Thermo Anemometer VT110 VT 115

Hotwire thermo-anemometer

VT 110 – VT 115

KEY POINTS

– Easy to use

– Adjustable backlight

– Automatic average

FUNCTIONS

Airflow calculation

Airflow calculation with cone

Selection of units (air velocity, airflow

and temperature)

Hold function

Display of minimum and maximum

values

Adjustable auto shut-off

Backlight

Airflow detection

Selection of cone

Dimensions of rectangular and

circular duct

Automatic average

Air velocity compensation in

atmospheric pressure

– Hold-min-max functions

– Selection of units

– Debit calculation

TECHNICALS FEATURES

Measuring element Hotwire air velocity :

Ambient temperature :

Display

Probes VT 110 :

VT 115 :

Cable

Housing

Keypad

Conformity

Power supply

Battery life

Ambience

Operating temperature (instrument)

Operating temperature (probe)

Storage temperature

Auto shut-off

Weight

SPECIFICATIONS

1.Etablies dans des conditions de laboratoire, les exactitudes présentées dans ce document seront maintenues sous réserve d’appliquer les compensations nécessaires ou de se ramener à

des conditions identiques.

Measuring

units

Measuring range Accuracy

1.Resolution

Velocity (hotwire)

m/s, fpm, km/h From 0.15 to 30 m/s

From 0.15 to 3 m/s : ± 3% of

reading ± 0.05 m/s

From 3.1 to 30 m/s : ± 3% of

reading ± 0.2 m/s

0.01 m/s

0.1 m/s

Airflow

m³/h, cfm, l/s,

m³/s

From 0 to 99 999

m³/h

±3% of reading ±0.03 x area

(cm²)

1 m³/h

Temperature

°C, °F From -20 to +80 °C

± 0.3% of reading ± 0.25 °C

0.1 °C

1.Etablies dans des conditions de laboratoire, les exactitudes présentées dans ce document seront maintenues sous réserve d’appliquer les compensations nécessaires ou de

se ramener à des conditions identiques.

250 g

Adjustable from 0 to 120 min

From -20 to +80 °C

From 0 to +50 °C

From 0 to +50 °C

Neutral gas

180 hours

4 batteries AAA LR03 1.5 V

Directives EMC 2004/108/CE and EN 61010-1

5 keys

ABS, protection IP54

Straight, lenght : 2 m

Telescopic hotwire probe bent at 90°

Stainless hotwire probe

4 lines, LCD technology. Sizes 50 x 36 mm.

2 lines of 5 digits with 7 segments (value)

2 lines de 5 digits with 16 segments (unit)

NTC sensor

Thermistance with a negative

Temperature coefficient.

kiray-250x250

Kiray Infra Red Thermometer Up to 1850 degree Celcius

Infrared thermometer

Kiray 300 is a thermometer used to

diagnose, inspect and check any temperature. Thanks to its

elaborated optical system with a dual laser sighting, it allows easy

and accurate measurements of little distant targets. The

KIRAY300 instrument has an internal memory which can save up to 100

measurements. Compatible with thermocouple K probe.

Spectral response…………………..8 – 14 μm

Optical……………………………………D.S : 50:1 (50.8 mm at 2540 mm)

Temperature range………………….From -50 to +1850°C

Accuracy*………………………………From -50 to +20°C : ±3°C From +20 to +500°C : ±1% ±1°C From +500 to +1000 °C : ±1.5% From +1000 to +1850°C : ±2%Infrared repeatability……………….From -50 to +20°C : ±1.5°C From +20 to +1000°C : ±0.5% or ±0.5°C From +1000 to +1850°C : ±1%

Display resolution…………………..0.1°C

Response time………………………..150 ms Emissivity………………………………Adjustable from 0.10 to 1.0 (pre-set at 0.95) Over range indication …………….Display indication : « —- »Dual laser sighting………………….Wavelength : from 630 nm to 670 nm Output < 1mW, Class 2 (II) Positive or negative temperature indication…………….Automatic (no indication for a positive

temperature) (-) sign for a negative temperature Display…………………………………..3 lines, 4 digits with backlighted display

LCD
Auto-extinction ………………………Automatic after 7 seconds of inactivity High/low alarm………………………..Flashing signal on display and beep signal with adjustable thresholds Power supply………………………….Alkaline 9V battery Autonomy………………………………95 h (inactive laser and backlight)15 h (active laser and backlight) Use temperature……………………..From 0 to +10°C for a short period

From +11 to +50 °C for a long periodStorage temperature

……………….From -10°C to +60°C Relative humidity……………………From 10 to 90%RH in operating mode and lower than 80%RH in storage Dimensions…………………………….200 x 140 x 50 mmWeight……………………………………320 g (included battery) Memory………………………………….100 temperature values Please make sure that the target is larger than the size of the laser sighting.

Technical features Distance from the target

KIRAY 300 Infrared thermometer

black-ball-250x250

Black Ball Thermometer for Heat Radiation Measurement

The human body is comfortable only in an environment where the

temperature and the air movements are kept within established limits.

For the comfort and good health of human or animals, the black ball

thermometer gives a direct measurement of the average radiant

temperature.

This temperature, perceived by the body, is radiated by all surrounding

surfaces, walls, floor, furniture and equipment.

The black ball thermometer is particularly useful in working area’s

veterinary laboratories and animal breeding.

Developed and manufactured

by KIMO, the Black Ball

Thermometer is for measuring

radiant temperature.

Based on the black body

principle, it consists of one

sphere, which is equipped with

a liquid expansion

thermometer, Pt 100 or

thermocouple temperature

probe .

It’s an accurate, reliable and

user-friendly instrument.

It’s also adaptable on every

types of thermometers.

 

Sphere

Hollow in brass, ø70 mm or ø150 mm

Thickness 6/10 mm

Coating

Multi-coat paint,

High temperature 600 °C,

Mat black with 0.95 average emission coefficient

Standards

Complies with the recommandations of the NF ISO

7726 Std relative to then ”thermal environment”,

X35-201 and X35-202 Std relative to the ”thermal

constraints of the working man”

sound-meters-250x250

Digital Sound Meters and Dosimeters

Sound level meter

Integrating-averaging with storage function

Five Different Measurement MODES

– Mode 1 :

Conventional sound level meter

– Mode 2 :

Conventional sound level meter with storage.

– Mode 3 :

Conventional and integrating-averaging sound level meter

– Mode 4 :

Integrating-averaging sound level meter with storage.

– Mode 5 :

Sound level meter “calculator” of two sound sources.

Measured Valve

Result & Additional Information

– Maximum and minimum values, peak values

– L01-L10-L50-L90 s

tatistics distribution of measured values.

– Presence and percentage of overload input stages, measurement time.

– Residual autonomy of batteries or battery, measuring capacity remaining.

Data Display

The DB200 sound level meter is supplied with

LDB200 software for display data and measurement report printing.

– Weighted sound level :L

– Equivalent continuous level :

Leq

– Sound exposure level : LE- Peak pressure level :

Lpk

I/O Interface

Launching and stopping of the measurement by external control.

Detection of sensitive levels for alarms activation

Analogue output 0-10V DC.

Standard

As per following standards :

Sound level meter : NF EN 61672-1

(2003)- NF EN 60651 (1994) – NF EN 60804 (2000).

CE conformity: EN 61010 – EN 61000

generic and as per product standards.

sl100-200-250x250

 SL 100 and SL 200 Solar Power Meters

Solarimeter

SL 100

Solar irrigation measuring rang

from 1 W/m2 to 1300 W/m 2

Energetic exposure measuring rangeFrequency of measurement

Accuracy

Calculation frequency (W/m2) Capacity of measurement (Wh/m2)

Operating temperature

Storage temperature

Housing dimensions

Autonomy

Power supply

Electronic

Electronic board

Conformity

Measurement and spot check of solar power in W/m2

– instantaneous,

– average,

– min./max. values,

– hold function

Calculation of energetic exposure in Wh/m

2 during timed dataset

Results (Wh/m2) saved when instrument is switched off

Solarimeter

SL 100

Portable autonomous solarimeter can measure solar irrigation for the control

of photovoltaic and thermal installations on test or on site:

Measurement and spot check of solar power in W/m2

– instantaneous,

– average,

– min./max. values,

– hold function

Calculation of energetic exposure in Wh/m2

during timed dataset

Results (Wh/m2) saved when instrument is switched off

Solarimeter

SL 100

Technical features

Easy to use, for immediate information

Evaluation of generated electric power,

optimum orientation of solar panels, and

performances follow-up.

Choice and determination of

thermal or photovoltaic generators features.

SL 100

Spectral response

Nominal sensitivity

Response in cosine